Lauritsen, Charles Christian (1929-01-01) Electron emission from metals in intense electron fields. http://resolver.caltech.edu/CaltechETD:etd-10082004-113543


Type of Document Dissertation
Author Lauritsen, Charles Christian
URN etd-10082004-113543
Persistent URL http://resolver.caltech.edu/CaltechETD:etd-10082004-113543
Title Electron emission from metals in intense electron fields
Degree PhD
Option Physics
Advisory Committee
Advisor Name Title
Robert Andrews Millikan Committee Chair
Keywords
  • none
Date of Defense 1929-01-01
Availability unrestricted
Abstract
NOTE: Text or symbols not renderable in plain ASCII are indicated by [...]. Abstract is included in .pdf document.

The behavior of a fine wire placed axially in a cylindrical anode is investigated.

A brief account is given of the more recent literature dealing with the subject.

A quartz tube which has been found particularly suitable and convenient is described. As it is not possible to outgas the ends of the filament and the supports, these parts have been shielded from the field.

The usual source of high potential consisting of transformer, rectifier and condensers is used.

A description is given of a method for measuring potentials from a few volts up to 25,000 volts. Use is made of a galvanometer and series resistance, and it is thought that the range can be extended to at least 100,000 volts.

With heat treated wires results are obtained in good agreement with earlier work, but it is shown that with such wires an appreciable current is obtained only after a break has occurred in the surface of the wire. The resulting characteristic depends only on the power available during the break and is shown to obey the empirical equation: [...].

Microtographs are presented which makes it plausible that the potential gradient may exceed 40 million volts/cm without producing currents in excess of [...] amperes and that the gradient is probably [...] volts/cm or more when reasonably large currents are obtained.

With untreated wires a "loop phenomenon" is described which is thought to be due to positive ions from the anode. Heating the tube in an electric furnace is shown to have a great influence on the emission in this case. Microphotographs show that the diameter of such a wire decreases with use.

With thoroughly outgased wires the emission is not changed when the tube is submerged in liquid air, and the heating of the filament up to 1400[degrees]K increases the emission only a few percent.

Files
  Filename       Size       Approximate Download Time (Hours:Minutes:Seconds) 
 
 28.8 Modem   56K Modem   ISDN (64 Kb)   ISDN (128 Kb)   Higher-speed Access 
  Lauritsen_cc_1929.pdf 1.44 Mb 00:06:41 00:03:26 00:03:00 00:01:30 00:00:07

Browse All Available ETDs by ( Author | Option )

If you have more questions or technical problems, please Contact the Caltech Library System.